2.2-kW IPMSM, dual-voltage-forming AFE, CVC
===========================================

This example simulates a 2.2-kW interior permanent-magnet synchronous machine (IPMSM)
drive whose active front end (AFE) uses dual-voltage-forming control [#Mou2025]_ and is
connected to a weak grid. The grid-side converter regulates both the DC-bus voltage and
its output voltage magnitude without a cascaded DC-bus voltage controller: the external
power fed to the DC bus by the drive is estimated by a disturbance observer and fed
forward. The machine-side converter uses sensorless current-vector control (CVC). The
two control systems are independent: they have different sampling periods, and their
carriers are not synchronized. The system model is otherwise the same as in
:doc:`/drive_examples/current_vector/plot_2kw_ipmsm_afe_cvc`, except for the weak grid.

"""

# %%
from math import pi

import matplotlib.pyplot as plt

import motulator.drive.control.sm as sm_control
from motulator.drive import model as drive_model
from motulator.drive import utils as drive_utils
from motulator.grid import control as grid_control
from motulator.grid import model as grid_model
from motulator.grid import utils as grid_utils

# %%
# Compute base values based on the nominal values of the machine and the grid converter.

nom_m = drive_utils.NominalValues(U=370, I=4.3, f=75, P=2.2e3, tau=14)
base_m = drive_utils.BaseValues.from_nominal(nom_m, n_p=3)
nom_g = grid_utils.NominalValues(U=400, I=5, f=50, P=2.2e3)
base_g = grid_utils.BaseValues.from_nominal(nom_g)

# %%
# Configure the system model. The two converters are fed from the same DC bus. The grid
# is weak: its inductance is 0.74 p.u.

afe = grid_model.VoltageSourceConverter()
inv = drive_model.VoltageSourceConverter()
dc_bus = drive_model.DCBus(C_dc=470e-6, u_dc=650, converters=[afe, inv])

ac_filter = grid_model.LFilter(
    L_f=0.15 * base_g.L, R_f=0.05 * base_g.Z, L_g=0.74 * base_g.L
)
ac_source = grid_model.ThreePhaseSource(w_g=base_g.w, e_g=base_g.u)
grid_sys = grid_model.GridConverterSystem(
    afe, ac_filter, ac_source, pwm=True, dc_bus=dc_bus
)

par = drive_model.SynchronousMachinePars(
    n_p=3, R_s=3.6, L_d=0.036, L_q=0.051, psi_f=0.545
)
machine = drive_model.SynchronousMachine(par)
mechanics = drive_model.MechanicalSystem(J=0.015)
drive_sys = drive_model.Drive(machine, mechanics, inv, pwm=True, dc_bus=dc_bus)

mdl = drive_model.CompositeModel({"grid": grid_sys, "drive": drive_sys})

# %%
# Configure the control systems. The grid-side control runs at 10 kHz (5-kHz switching
# frequency) and the machine-side control at 8 kHz (4-kHz switching frequency). The
# gains of the dual-voltage-forming controller are given in per-unit values of the grid
# converter [#Mou2025]_.

cfg_g = grid_control.DualVoltageFormingControllerCfg(
    i_max=1.5 * base_g.i,
    L=0.3 * base_g.L,
    C_dc=470e-6,
    R=0.05 * base_g.Z,
    k_d=base_g.u / base_g.p,
    alpha_dc=0.15 * base_g.w,
    alpha_o=2 * base_g.w,
    alpha_o_dc=1.2 * base_g.w,
    k_v=6,
    alpha_c=6 * base_g.w,
    u_nom=base_g.u,
    w_nom=base_g.w,
    T_s=100e-6,
)
ctrl_g = grid_control.GridConverterControlSystem(
    grid_control.DualVoltageFormingController(cfg_g)
)

est_par = par  # Assume accurate model parameter estimates
cfg_m = sm_control.CurrentVectorControllerCfg(
    i_s_max=1.5 * base_m.i, alpha_o=2 * pi * 100, T_s=125e-6
)
vector_ctrl = sm_control.CurrentVectorController(est_par, cfg_m)
speed_ctrl = sm_control.SpeedController(J=0.015, alpha_s=2 * pi * 4)
ctrl_m = sm_control.VectorControlSystem(vector_ctrl, speed_ctrl)

# %%
# Set the references and the external load torque. The speed is reversed under load,
# after which the drive regenerates power to the grid.

ctrl_g.set_dc_bus_voltage_ref(650)
ctrl_g.set_ac_voltage_ref(base_g.u)
ctrl_m.set_speed_ref(lambda t: (t > 0.1) * base_m.w_M - (t > 0.7) * 2 * base_m.w_M)
mechanics.set_external_load_torque(lambda t: (t > 0.4) * nom_m.tau)

# %%
# Create the simulation object and simulate. The clocks of the two control systems are
# not synchronized: the machine-side control starts 40 µs after the grid-side control.
# The results of each model and its control system are available by the model names.

sim = drive_model.Simulation(
    mdl, {"grid": ctrl_g, "drive": ctrl_m}, t_start={"drive": 40e-6}
)
res = sim.simulate(t_stop=1)
res_drive = drive_model.SimulationResults(res.mdl.drive, res.ctrl.drive)
res_grid = grid_model.SimulationResults(res.mdl.grid, res.ctrl.grid)

# %%
# Plot the drive and grid-side results in per-unit values. The active power reference
# shown is the equivalent reference formed by the dual-voltage-forming controller from
# the estimated external power and the DC-bus energy error.

# sphinx_gallery_thumbnail_number = 3
drive_utils.plot(res_drive, base_m)
grid_utils.plot_control_signals(res_grid, base_g)

# %%
# Plot the DC-bus voltage and the power balance: the estimated external power fed to the
# DC bus (the estimated disturbance power plus the grid power and the resistive losses
# of the filter) follows the mechanical power plus the losses (mainly the stator
# resistive losses), and the power drawn from the grid follows it with the delay of the
# current dynamics in the weak grid.

ctrl_ts = res.ctrl.grid
p_loss = 1.5 * cfg_g.R * abs(ctrl_ts.fbk.i_c) ** 2
p_ext = ctrl_ts.fbk.p_dis + ctrl_ts.fbk.p_g + p_loss
p_M = res.mdl.drive.machine.tau_M * res.mdl.drive.machine.w_M
fig, (ax1, ax2) = plt.subplots(2, 1, sharex=True)
ax1.plot(res.mdl.t, res.mdl.drive.dc_bus.u_dc, label=r"$u_\mathrm{dc}$")
ax1.plot(
    ctrl_ts.t,
    ctrl_ts.ref.u_dc,
    "--",
    ds="steps-post",
    label=r"$u_\mathrm{dc}^\mathrm{ref}$",
)
ax1.set_ylabel("Voltage (V)")
ax1.legend()
ax2.plot(ctrl_ts.t, -p_ext / 1e3, ds="steps-post", label=r"$-\hat{p}_\mathrm{ext}$")
ax2.plot(
    ctrl_ts.t, -ctrl_ts.fbk.p_g / 1e3, ds="steps-post", label=r"$-\hat{p}_\mathrm{g}$"
)
ax2.plot(res.mdl.t, p_M / 1e3, label=r"$\tau_\mathrm{M}\omega_\mathrm{M}$")
ax2.set_ylabel("Power (kW)")
ax2.set_xlabel("Time (s)")
ax2.legend()
plt.show()

# %%
# Plot the grid-side waveforms around the load torque step. The converter current
# increases within a few milliseconds, as the estimated external power is fed forward.

grid_utils.plot_grid_waveforms(
    res_grid, base_g, t_lims=(0.39, 0.45), plot_pcc_voltage=False
)

# %%
# .. rubric:: References
#
# .. [#Mou2025] Mourouvin, Nurminen, Hinkkanen, Routimo, "Direct DC-bus control for
#    grid-forming converters: Toward the concept of dual-voltage-forming converters,"
#    IEEE Trans. Power Electron., 2025, https://doi.org/10.1109/TPEL.2025.3537332