Six-Pulse Diode Bridge#
The figure below shows a six-pulse diode bridge rectifier, where the inductor \(L_\mathrm{dc}\) is placed in the DC link. For simplicity, a three-phase supply voltage is assumed to be stiff. The DC current dynamics are
where \(i_\mathrm{L}\) is the DC-bus current, \(u_\mathrm{di}\) is the voltage over the diode bridge, \(u_\mathrm{dc}\) is the DC-bus voltage, and \(L_{\mathrm{dc}}\) is the DC-bus inductance.
Six-pulse diode bridge rectifier.#
Six-pulse diode bridge rectifier.#
The voltage-source converter described in the Voltage-Source Converter document is extended with this diode bridge model in the motulator.drive.model.FrequencyConverter
class. Examples using the six-pulse diode bridge can be found in 2.2-kW induction motor, diode bridge and 2.2-kW PMSM, diode bridge.